Furthermore, if the point is attached to the Earth (e.g., a mountain peak), then altitude (height above sea level) is called elevation.In a two-dimensional Cartesian space, height is measured along the vertical axis (y) between a specific point and another that does not have the same y-value. If both points happen to have the same y-value, then their relative height is zero. In three-dimensional space, height is measured along the vertical z axis, describing a distance from (or "above") the x-y plane.

View More On Wikipedia.org
  1. A

    syphon height

    Hi fellas, Does the height of a toilet flush syphon have any bearing on the power of the flush? thanks dave
  2. A

    gas pressure and height

    spent the day checking working pressures on boilers in a block of flats, we were checking existing pipe sizing before replacing all the boilers i was doing the working pressure at the boiler, while my colleague (who is incidentally a blithering idiot), was at the meter monitoring the pressure...
  3. M

    Low hot water pressure

    I've just fitted a new thermostatic shower (made sure I bought a low pressure type) but there's still not enough pressure for me to get wet with hot water without running around. I figure that the only way forward is to raise the cold water tank in the loft. Due to the roof height, I can't...
  4. H

    Boiler in loft - gas pressure.

    Hello, I plan to have my new boiler fitted in the loft, but I've been told that some people who have done have not had the pressure required in a higher location for the boiler to light. What is the likelyhood of this posing a problem to me? Is this something that is a common issue?
  5. M

    installing a back boiler oil link up in a bungalow, anyway around it?

    Hay guys i have never attempted a back boiler oil link up before, i have a customer who has purchased a back boiler wood burning stove and is looking to link it up 2 the oil heating to heat the water and rads! Only problems is that its a bungalow and the hwc is on the same floor as the stove so...
  6. S

    Concealed shower Arm

    Hello people, I am due to fit a concealed shower valve along with shower arm. I will have to build a studd wall to conceal the thermostatic valve and the length of pipe to take the water to the shower arm/head. I need to know how to connect the shower arm to the studd wall and the best order...
  7. E

    Boiler flue height

    This is my first post so please forgive me if I've put this in the wrong section. We are in the process of having an Okofen Pellematic boiler (that will provide our central heating and hot water) installed in our garage. The flue went up yesterday and I am concerned about the height of it...
  8. M

    Heights for certain sanitary ware

    Hi guys im currently on a plumbing apprentiship in my second year and on one of my latest assignments theres a question which asks: State what Height you would fit the following sanitary ware a. wall mounted Basin b. Belfast sink c. Adult Urinal and Juniour urinal bowls. Many thanks
  9. J

    Minimum height of gas boiler flue void for inspection hatches?

    Hi I have a Powermax 155x situated in the middle of my flat which has a boiler flue running the width of the flat (5m) to an outside wall. The flue runs along the ceiling void, and is concealed. The void is only 96mm in height, I understand that they are usually much taller. One contractor has...
  10. P

    Height of vent pipe formula

    Does anybody know the formula used to calculate the height of the underside of the open vent pipe to the water level in the cwsc? Thanks
  11. T

    Oil Tank Below Boiler Level problem

    Hi, Recently on the advice of a plumber we moved our oil tank level from above the level of the tank, to further down our garden. We were told that it would be fine as he would use a tiger loop which would draw the oil up to the boiler no problem. The bottom of the oil tank is around 2.5/3...
  12. J

    Height of washing machine exit pipe...

    Hi all... Fitted washing machine waste using usual setup of vertical pipe into trap then up and out through wall. Existing hole out through wall is quite high though - about 15inches above the trap. Can I use that hole, or do I have to make another lower down? Have tried using the existing...
  13. M

    Rad size and attic requirement

    Two questions here. I have bought a double rad with single fin which is 1800 x 600 and it produces 10k BTU's. When i boughti it ages ago and thought nothing of it, but since then i have come round to thinking single fin rads cant go that high. Or am i wrong here. It did say on the packaging...
  14. B

    Disabled raised height wc pan + cistern??????

    Hi guys was wondering if any one knew of any sites/merchants selling them for a reasonable price????? have had quotes of around 250 to 300 quid!!! i thinks this seem a tad expensive! Dosent have to be armitage shanks contour, just any make of reasonable quality.....
  15. S

    Header tank height?

    I want to move my ch header tank into the eaves of the roof in a attic bedroom, it means it will be about 2 foot lower than its original position, the bottom of the tank will be around a foot higher than the highest rad. Is this OK? Thanks in advance!:confused:
  16. G

    Toilet waste lower than soil pipe in wall by 50mm

    Hello All. I have been reading a few threads on the forum, notably "Offset toilet waste connector (small offset)?" in the main Plumbing Forum, but wondered if anyone had any thoughts to help me? I want to replace the toilet in my bathroom. Presently the toilet sits on a 50mm wooden plinth -...
  17. B

    Bayonet Fitting

    Just a quick Question:How much would it cost just to fit a bayonet fitting not a cooker (estimates) thanks Becky
  18. P

    Height from bath to shower valve

    I started a bathroom today and I'm putting a bar mixer over the new shower bath, I should have stood in the old bath before I ripped it out to postion the height of the new shower valve. Basic question I know but does anyone have a measurement ?, ideally from the floor. I Know baths vary in...
  19. A

    Shower enclosure height restrictions for low ceilings?

    I was wondering whether theres a minimum gap that should be kept between a shower enclosure and the ceiling? I have a bathroom (not a wet room) with a low ceiling and raised floor, most standard shower enclosures would come very close to the ceiling and googles not been of great help, so I...
  20. S

    Whole New Solid Fuel Heating - Thermosyphon Height & Thermal Store Size?

    Hello! I am renovating a cottage and am starting from scratch with the heating system because the original boiler consisted a massive iron tank with 5 immersion heaters in it, which cost a fortune to run and wasn't all that effective, and the radiator circuit is very very old and needs to be...