"Sealed with a Kiss" is a song written and composed by Peter Udell and Gary Geld. It first became a hit in 1962 for Brian Hyland. The original recording of "Sealed with a Kiss" was by the Four Voices which was released as a single in May 1960 without becoming a hit. Jason Donovan later had an international number one hit with the song.
The lyrics are from the point of view of one of two lovers who have had to part ways over the summer. The narrator promises the lover who has had to leave that he will send his love and dreams in daily letters "sealed with a kiss". The two also bind each other to a pledge, under seal of a kiss, that they will reunite in September.
a regular customer has asked me to fit a new flueless gas fire :eek: i dont want to fit it but i feel my hands are a bit tied if you know what i mean, i get a fair bit of work from him.
my question is the ventilation i know is 100cm sq its the path i cant vent it between 2 rooms or it will...
pauls
Thread
appliance
burner
burner pressure
cold
flame
gas
gas fire
high
hose
install
job
pressure
price
problem
safety
sealed
test
vent
ventilation
wall
water
web
work
We have moved into our current home a few months ago. It's a very old house with relatively haphazard plumbing. Things worked fine until recently when I noticed that the pressure in the sealed system is on 0.5bar and it's not heating the upstairs radiators.
Got a plumber that had done some work...
ashimashi
Thread
bar
boiler
central
central heating system
combi
filling loop
heating system
leak
mains
not heating
pipe
plumber
plumbing
pressure
problem
pump
radiators
screw
sealed
system
valve
water
My new house has 25 x 2.5mm Uponor MLC flow and return pipes from/to the boiler. In the loft the pipework feeds the sealed system comprising cylinder coil, upstairs radiators and downstairs underfloor heating through separate 20 x 2.25mm MLC pipes.
The radiators and coil are served by an...
Johnny B
Thread
boiler
central heating system
circulation
condensing
copper
cylinder
hot
hot water
hot water system
loft
motorised valves
pipe
pipes
pipework
plumber
pump
radiators
sealed
sizing
system
underfloor
underfloor heating
valves
water
wide
Hi all
Got a lot of rad valves to change in various houses tomorrow - think i've drawn the short straw:eek: - anyway, I have a bung kit on the van and never used it, but was just wondering if any of you guys have?
I've no problem with the drain downs but would use bung kit if quicker
Any...
With a sealed combi system obviously the heating system is filled up via the filling loop to a certain pressure, so when it comes to bleeding the radiators then pressure will obviously drop and need filling, am i right so far? Its an old worcester 24i combi boiler, ive searched for what pressure...
peteeyres
Thread
24i
bar
bath
bleed
bleeding
boiler
central heating system
cold
combi
combi boiler
drain
filling loop
pressure
problem
question
radiators
sealed
silly
switch
system
valve
worcester
Does anyone know as where to get a service key from for the following meter?
I have told the woman at the house its faulty as the dials will not turn and told her to get in touch with water board to get a new one fitted for free but she wont for odious reasons - Free water
So I wanted to see...
Lag1rich
Thread
free
meter
oil
sealed
service
supply
water
water meter
Can this opening be sealed from the inside, so stopping the draught coming into the hallway? Or does it need this airflow. I understand it needs to be vented from the outside, so definitely do not seal this side.
The pipe is sleeved and is bringing in a big draught into the hallway.
ps...
marsaday
Thread
central
central heating
coming
gas
heating
house
inside
pipe
seal
sealed
sealing
wall
I reported on this forum last weekend my success in cleaning out 552 burner and removing lint trapped in filter. This cured a yellow burning flame - very pleased with result EXCEPT:-
I am getting a lot of expansion clicking and ticking now from what I reckon is the burner when cycling on and...
jirams
Thread
after
assembly
baxi
boiler
burner
career
clean
cleaning
corgi
expansion
filter
find
flame
gas
insurance
job
law
noise
pipes
question
remove
sealed
tips
trade
water
water pipes
yellow
It is sleeved and then goes into the meter.
Can this opening be sealed from the inside, so stopping the draught coming into the hallway? Or does it need this airflow. I understand it needs to be vented from the outside, so definitely do not seal this side.
marsaday
Thread
building
comes
gas
house
inside
leak
sealed
through
vented
wall
where
ok, quick recap 1, 3 storey house 2, all rads on top floor and 2nd floor heating ok 3, 5 rads on ground with one new rad added today, bled all rads, 4, put heating on manual kitchen rad and dinning room rad roasting hot but the 2 in the hall way and the 2 in the living room stone cold 5, opened...
curly
Thread
air
bleed
boiler
boilers
central heating system
cold
cold radiator
combi
filling loop
gas
help
hot
hot rads
hot water
kitchen
manual
not heating
pipe
problem
pump
radiator
screw
sealed
still
system
vent
water
Oh dear, seems Gas Safe & the HSE have been a bit busy over the last couple of days. New TBs released saying that after 31 Dec 12, flues in voids with no inspection hatches, that are otherwise working safely, become AR.
CMairiD
Thread
boiler
boilers
buy
difficult
electric
find
flues
gas
gas safe
hose
keston
loft
safe
sealed
supply
tools
work
Stupidly I secured the PRV shut temporarily so the heating would still work while I got a new one to replace the leaking PRV. My wife then added some water through the filling loop without asking me - I just checked the pressure and it has been running at 4.7 bar, of course I shut it of...
Matt101
Thread
bar
boiler
boilers
central
central heating system
could
damaged
eco
ecotec
expansion
expansion vessel
filling loop
help
leaking
oil
pressure
radiators
seal
sealed
switch
system
vaillant
vessel
water
work
Hi folks, called out to the above boiler (balanced flue), going to lockout. Everything very sooted up. Nothing has been done to it for about 10 years.
Motor was screeching so changed bearings, set pump pressure to 100psi as per tag on burner, cleaned out baffles, combustion chamber etc and...
I had a brand new Vaillant ecotec 837 boiler fitted in June and ever since then there have been intermittent rotten egg smells coming from the boiler. There are no hot water outlets in the room where the boiler is, it seems to emanate from the boiler/boiler cupboard itself.
The gas safe...
deev256
Thread
boiler
boilers
combi
condensate
drains
eco
ecotec
fitting
gas
gas safe
hot
hot water
no hot water
oil
pipe
pipes
pipework
plumbing
polish
safe
sealed
smell
vaillant
water
work
With this cold snap and the cold winter forecast, I recommend that instruments such as FGA, multimeters and other test instruments are taken inside during the night and if possible put them in the front of your vehicle between jobs.
Modern electronic instruments do suffer from condensation as...
kevin@gesuk
Thread
analysers
cold
cold weather
condensation
damage
drills
electronic
flue
gas
gravity
guage
inside
jobs
safe
safety
screen
sealed
test
van
water
weather
winter
work
Hi, can anyone help me to adjust my honeywell frost stat .
It has the round tamper proof cover to protect "adjustment" but I believe mine is set too high as CH coming on all night at present.
How do you remove the tamper proof cover to adjust the setting down a notch or two ?
Thanks.
Button216
Thread
blank
boiler
combi
combi boiler
frost
gas
high
honeywell
main
mains
plug
power
remove
safe
safety
screw
sealed
wall
Hello,
I've come across a horrible example of how not to seal around a kitchen sink - there's excess smears and then gaps in equal measure so it looks terrible as well as being ineffective.
So I'm looking for a product which will remove the old silicone and leave the surfaces in a suitable...
wheeto
Thread
kitchen
remove
removing
residue
seal
sealed
shape
silicone
sink
Fitted a Worcester 37 CDI minimum distance from ceiling and wall in a corner of a kitchen pipes running up behind the boiler and flue turrent is right up against the wall with the plastic collar. Sealed outside with cement and fitted collar but Finding it hard to get a trowel in-between the...
efficient
Thread
boiler
ceiling
flue
gas
gas safe
hose
internal
job
jobs
kitchen
pipes
rubber
safe
seal
sealed
wall
worcester
Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website. For the best site experience please disable your AdBlocker.