Search the forum,

sealed

"Sealed with a Kiss" is a song written and composed by Peter Udell and Gary Geld. It first became a hit in 1962 for Brian Hyland. The original recording of "Sealed with a Kiss" was by the Four Voices which was released as a single in May 1960 without becoming a hit. Jason Donovan later had an international number one hit with the song.
The lyrics are from the point of view of one of two lovers who have had to part ways over the summer. The narrator promises the lover who has had to leave that he will send his love and dreams in daily letters "sealed with a kiss". The two also bind each other to a pledge, under seal of a kiss, that they will reunite in September.

View More On Wikipedia.org
  1. fango7

    Frame not sealed to tray

    Hi all Plumber who fitted shower frame didnt put sealent behind frame to tray before fitting frame. Now leaks when water gets into frame and down into downstairs wall Another plumber has sealed inside area whwre it is shown yellow , which i get is not ideal. i was going to just seal a thin...
  2. Desktop987456

    Room sealed boiler - location

    I have a open flue old boiler (natural draft for combustion) installed on outside wall. Before winters want to install a heat only condensing boiler (room sealed), cannot install it at the current location as it is open to weather effects (rain and sun light in summers). I cannot install it in...
  3. M

    Sealed system grabbing air

    Any ideas why a sealed system with a combi could be grabbing air. The upstairs rads have air in and the system reads 3 bar cold. When the air is bleed out the system returns to 1 bar or less. It's an ideal instinct boiler basically a logic.
  4. U

    Should you silicone around thermostatic mixer valve

    Hi all, We have a Mira agile/pronta shower mixer valve attached to a tiled wall. It doesn't say in the manual but do you need to silicone around the periphery of the mixer where it meets the tiled wall? Or are they internally sealed or doesn't matter if water seeps into it from splashing etc...
  5. R

    Can this leak have sealed itself and should I leave it alone?

    Hi When my boiler was serviced this year the plumber found the leak as shown in the photo. I was told that the problem may have resolved itself but if not I may need a new boiler. I have three questions please: 1) What has caused this problem? 2) Now I know the problem is there (it's normally...
  6. V

    How to bleed sealed system

    Looking at a friend's system yesterday. The boiler is refusing to fire and showing a fault code indicating no water flow. The pressure vessel gauge shows a pressure of 1 bar. I concluded the schematic was roughly as shown here I'm concerned that the pressure vessel gauge could still register...
  7. D

    help draining sealed ch system

    Hello I have a sealed ch system that I am trying to fit a new 3 way valve (leaking) and a water pump (nocking) in one go, problem is that the two shut off valves at the pump are solid screw type and will not turn even with a large bladed screwdriver so I am stuck. Looks like my only option will...
  8. S

    Wood pellet system - open or sealed system

    Hi there, Looking at the manual for a lanordica Exflame costanza pellet boiler, it is designed for a 'closed' system - presumably them mean sealed. I've seen manuals for other pellet boilers advising they can be installed on open or sealed systems, I'm based in ROI but can anyone advise (for UK...
  9. M

    Sealed system kits

    I want to install one of these when converting a vented to sealed system. The only issue being the boiler manufactorys ask for the prv to be fitted on the flow as close to the boiler as possible. However if installing this kit I would need to fit on the return, due to the expansion vessels...
  10. T

    help required with sealed leaking bath

    I have a sealed bath that is leaking into my kitchen when emptied, unfortunately the pervious owner has tiled all around the bath without leaving an access panel to the pipework/drain . is their a liquid sealant that i can use to fix the leak or do i have to remove all the tiles . I have tired...
  11. J

    Sealed system efficiency compared to open system

    Would switching to a sealed system from an open system save money/fuel?
  12. M

    PRV on sealed heating

    Just wondering if I can put the sealed heating pressure relief valve on the hot water return? As I can’t get relief pipe out where boiler and controls are 1604061267 just to add is an open vented conversion
  13. gingalig

    Dunsley removal and unvented conversion to sealed.

    Need to pick a couple of brains whilst exposing my chasm of limited understanding. Before I qualified, about 10 years ago we had a Dunsley neutraliser fitted, combining a Firebird oil boiler and a Hunter multifuel. Over time we've never really been happy with the set up and have a shower pump...
  14. W

    Pressure loss from sealed system stops when open/closing a zone with 'a leak'

    Hello all, Seeking any input on a matter that seems to defy logic and common sense. Sealed system Oil fired boiler (newish) feeding a large farmhouse from an annex with a good quality install/ pump etc that seems to be doing the job. The system is losing 1 bar per day for a long time. I...
  15. M

    Old joints are leaking, sealed with hemp - dried out ?

    Hello, I am new to this forum and have a question about some old plumbing around a hot water cylinder. The hot water cylinder wasn't used for 14 years and all pipes were drained. Turned the water to the hot water cylinder on and it seems that all joints on the copper tubing around the cylinder...
  16. eagleeye

    Gravity hot water to fully pumped / sealed

    One of our installers currently fitted a new heat only boiler to replace an old floor standing with gravity hot water. At the time he never fitted any valves or cylinder stat etc so I have been called back there to basically start again. Been there today to do it and found that he had the pump...
  17. P

    Air getting in to sealed system ... !!

    I am collecting air in one downstairs radiator which requires bleeding once per week and a small amount on the auto bleed valve on the hot water side of the system. However, there is no pressure drop until I bleed the rad which then drops about 0.1 bar. The system was flushed couple of months...
  18. S

    How to check if air tight trapped sealed gully was installed as designed?

    I have a Zip water heater installed in a cupboard under the kitchen island. There is not normally any discharge into the Zip "font" in the worktop other than maybe a small amount of near-boiling water. The Zip guy accused us of chucking dregs down there, which I categorically deny. There is a...
  19. S

    Removing a bottom fitted toilet seat from a sealed pan.

    My girlfriend and I just moved into a new apartment, and the toilet seat is in desperate need of replacing. I didn't think it'd be too much hassle, but I've run into a bit of trouble. The seat seems to be fixed from the bottom, but there's no way to access the bolt as its "inside" the toilet...
  20. D

    Saniflow plus - Possibly serviced improperly - Not sealed properly to soil pipe

    Hi from a householder amateur! I have a saniflow plus for over 5 years. For the last 2 years it "gets blocked" about every 6 months. I then call a guy to fix it. I am aware of what should not be put in saniflow etc. For the first time - I decided to open it up and investigate. I removed...
Creating content since 2001. Untold Media.

Newest Plumbing Threads

Back
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website. For the best site experience please disable your AdBlocker.

I've Disabled AdBlock