A fermionic condensate or Fermi-Dirac condensate is a superfluid phase formed by fermionic particles at low temperatures. It is closely related to the Bose–Einstein condensate, a superfluid phase formed by bosonic atoms under similar conditions. The earliest recognized fermionic condensate described the state of electrons in a superconductor; the physics of other examples including recent work with fermionic atoms is analogous. The first atomic fermionic condensate was created by a team led by Deborah S. Jin in 2003.

View More On Wikipedia.org
  1. S

    Condensate in cast iron pipe

    Hi there I'm looking to run a 32mm condensate into cast iron with a mcalpine mechanical boss adaptor. I need to make a 57mm hole and was wondering what's the best tool to use for it. The 57mm holesaws I can see say they do sheet metal but will they do the job on cast iron? Any help will be...
  2. M

    Condensate teed in to kitchen sink easte

    Anyone come across gurgling condensate traps on boilers? When the condensate line is tee'd in to the kitchen sink waste? Have managed to stop it by installing a inline aav adapter on the trap. Anyone else noticed this.
  3. S

    Question re: condensate pump on Greenstar 440

    Hi, The condensate pump on my Worcester Greenstar Highflow 440 CDI is flashing green and red simultaneously, halting after a few goes at starting up from power on. Is there anywhere I should be looking for obvious issues ahead of the plumber coming out in a few days? Thanks, Lou
  4. blundell

    Is this boiler condensate pipe trap past its best? ('07 Warmflow Utility US70HE System Oil Boiler)

    Hi! I've been chasing the smell under our stairs/cellar for so long and have had many things fixed one by one, the smell still remains, next investigation is the boiler! They say a picture is worth a 1000 words. Here's 4: The boiler is a condensing boiler, I think it's a "Warmflow Utility...
  5. T

    Why is my boiler condensate not emptying into the pipe?

    Previously no issues but now when I disconnect the condensate pipe from the boiler there is an audible air escape from the condensate pipe then the boiler happily drains into the pipe and you can hear it drain into the mains waste. Is this an air lock issue?
  6. R

    Condensate dripping from boiler flue - advice please

    I have an Alpha Intec boiler installed on my loft wall. The flue goes horizontally from the top of the boiler and passes through the wall, exiting high up in the gable end. The boiler was installed about 6 years ago. My attached garage joins the gable wall directly below the flue. I had the...
  7. F

    440CDI highflow Greenstar condensate leak no error boiler works

    Hi Leak is from condensate pump which seems to work fine when restarting boiler it pumps out. Puddle on floor every morning from condensate leaking no error codes heat and hot water working fine. Have ordered new nozzle for pump to hose.
  8. M

    Condensate lagged though wall

    Do most people lag 32mm in this case 40mm (1.5inch) as it passes through the wall cavity or just the external pipe? If lagging the pope in the cavity what's best to seal the lagging to the wall with. I'm thinking it wouldn't cement up well?
  9. W

    Condensate drain off & leak

    So I have a new Vaillant condensing boiler (ecoFIT pure). I can see the plastic condensate pipe that exits the boiler. The boiler is currently set to 62C, so should be condensing, but the condensate pipe never even gets warm to the touch even if the boiler's been on for a while - should it? The...
  10. S

    Baxi Platinum 28HE - Condensate problem

    Hi, Noob here Struggling with a Baxi Platinum 28HE. a few years ago, the boiler was (almost) completely rebuilt with about 99% new parts. but today, it stopped working with an E133 fault code. I checked the Condensate pipe and it wasnt blocked. I took the front panel off the boiler and it...
  11. L

    Valliant condensate issue

    Good morning, Hoping someone can provide some advice... I'm having an issue with my valiant boiler, the condensate pump keeps tripping, I believe the pipe may be blocked (probably frozen but I'm not sure) as when I disconnect the end and drain it I cannot blow through the pipe. The pipe goes...
  12. T

    Condensate drain off

    I’m currently getting quotes to install a new system boiler. The current boiler has the condensate drain off joined into the rainwater down pipe outside. One installer has said that it is fine to stay that way and two others have said that they will need to install a new soak away for the...
  13. L

    new boiler condensate

    Not sure if I have the right forum but looking as a homeowner for a bit of advice. Having a new combi installed, old boiler no condensate, got some quotes. One quote will remove kitchen units and under the counter fridge put in condensate pipe run for 8 ft about the through wall to outside...
  14. S

    Worcester boiler condensate won't drain.

    Good afternoon all, I have a Worcester boiler installed recently. It was moved from the first floor to the loft. Existing 22mm condense pipe was extended to the loft. It looks like the old pipe has no slope and prevents air to get into the boiler condensate trap, preventing condensate to drain...
  15. F

    Ideal Isar HE30 Condensate Trap

    Hi all, Got home today and the dreaded Ideal Isar boiler had stopped working on me. Error L:F flashing on the control panel Took the front off and noticed a small trickle of water dripping around a small copper pipe on the left hand side According to a few things that I've seen online the...
  16. G

    Condensate drain connection to rainwater drain

    I'm going to have to get by boiler replaced which means provision needs to be made for a condensate drain as the old boiler didn't have one. The boiler is in the garage, that is part of the house, if that makes sense. The house was built in 1999. There is no convenient internal drain. Outside...
  17. O

    Air break leak at condensate / washing machine waste connector

    Hello! DIY noob hear asking for advice on a leak from an air break. My undersink plumbing is a mess of pipes handling washing machine, dishwasher, and boiler condensate. When the washing machine runs, the air break overflows. The dishwasher is on too, the problem is worse. This used to happen...
  18. R

    Glowworm 30HXi condensate trap outflow speed

    Hi I inherited an LPG burning Glowworm 30HXi when I moved into my house some years ago. Great little boiler but had been neglected. I cleared a lot of debris out of the heat exchanger and chamber at base, on top of the condensate trap. I always flush several litres of water through the trap...
  19. A

    Condensate when the boiler is not running

    I’ve been having a few pressure drop issues with my heating system. One problem already diagnosed and sorted (thanks to this forum) was a leaking EV at the valve end (replaced) but I am still seeing a pressure drop (albeit slower than before 1.5 -1.4-1.3bar) and wanted to ask a question.... I...
  20. S

    How does a boiler sense the condensate pipe is blocked?

    How does a boiler sense the condensate pipe is blocked?. Boiler stopped working. I was told the condensate syphon was blocked and had to be cleared. I wondered how the boiler controls knew this?
Creating content since 2001. Untold Media.

Newest Plumbing Threads

Back
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website. For the best site experience please disable your AdBlocker.

I've Disabled AdBlock