Glowworm or glow-worm is the common name for various groups of insect larvae and adult larviform females that glow through bioluminescence. They include the European common glow-worm and other members of the Lampyridae, but bioluminescence also occurs in the families Elateridae, Phengodidae, and Rhagophthalmidae among beetles; as well as members of the genera Arachnocampa, Keroplatus, and Orfelia among keroplatid fungus gnats.
desperatly seeking manual for above combi boiler for tomorrow morning job
hot water running hot then goes cold after short while, then i think hot again.
been told apart from that the boiler works fine!
cheers:confused5:
Here goes! .. me and my very experienced mate are scratching our heads on this one!
set up - convention with 5 x rads and 1 x cylinder (y plan), 22mm flow and return with drop downs to all rads
Boiler is faulting on poor circulation F22 and F25 (glow worm HX 15)
What I've checked :-...
who's the pro on these boilers?
sealed h/o boiler, 'reset-+ full rate' keeps firing up for 5 sec's then cuts out at 5.5%co then starts again ??????
wasup?
Hi all,
Having a nightmare and hope someone can help. Boiler is leaking from pump, seems the gasket inbetween the plastic body and metal head has worn. However, I can't for the life of me find one and have worryingly read on one review that glow worm don't sell these gaskets seperately but...
Hello lads, anyone know where I'd get a gas valve for a chatsworth gas fire. The glow worm part number is 230502.
i haven't been able to source one. Tried a couple of websites. They indicate that they have it but when I go to purchase, it's not available. Glow worm in the UK say it's obsolete...
hi peeps I am best explaining this with picture
this should work right ? basically focus on the green return wire or switch live.
Thanks in advance for any help clarifying this.
Barbeck
Thread
attach
gas
glow
glow worm
glow-worm
room stat
wiring
worm
I have a glowworm micron 40ff and it has stopped working. The central heating pump runs and the motorised valve switches ok it's the boiler that's not firing up. I have checked the fuse on the pcb and that's fine and there's voltage going through the pcb but still nothing happening. Does anyone...
Jason1990
Thread
glow
glow worm
glow-worm
not working
plumbers
plumbing
working
worm
Have been to see the above today. Have tried disconnecting thermistors overheat fan and gas valve and have tested resistance and continuity of the loom. The fault persists is there anything anyone out there knows causes this or causes the PCB to fail with this error. Disconnecting the fan caused...
Hi all,
had a look at a glow worm 18sxi - boiler is locking out on F1 and occasionally F4, the boiler lites for about 5 secs then out, does it again etc etc. I noticed the boiler still has the old style seal which I am going to change but the earth nxt to the electrode seems pretty much burnt...
You know what they are like, a customer has just rung with this one. I have loads on next week and don't even want to go so if somebody can point me in the right direction with this I would be very-grateful.
Glow-worm 30 cxi, pre condencing, I fitted it about 7 ish years ago.
Ok on heating, but...
Morning gents, I am on my way to bed and thought to myself 'why didn't I ask on here?'
I then thought to myself 'do it now'
So I that is what I am doing :)
Swapped a couple of old worn out rad valves for TRV's today (one of those jobs where everything goes wrong...), should have taken 2-3 hours...
going to job in morning to check back boiler. customer saying pilot light cuts out after heating/water satisfied. im thinking
pump over run fault. dont work on may bbu now anything else you guys could point me towards?
hi all
cant find MI's for this boiler anywhere and it's currently non op.
need to know which way round the f & r pipes are pls :) (suspicion flow is rhs, return lhs)
many thanks
dan
Any1 had any dealings with this?
LPG fuel - heat only boiler
Faulty gas valve, changed for new.
Only 6 rads on the system, literally takes around 2mins for radiators to be bouncing! Insane!
Setting up the gas valve is a nightmare, need 10.5% - 0.004 ratio
However to achieve this im getting...
Hello all
i wounder if someone could help me.
About 6 months ago i had a new Glow worm combi boiler fitted, and ever since the boiler pressure has been rising resulting in me have to bleed the rads to lower the pressure.
The plumber has been back a couple of times and he says all it can...
Hi,
not sure whether to call in engineers yet. Sometimes in the morning heating does not come on and i have to turn boiler off and on and then it comes on. Pressure is 0.6 or 0.7 and used to be aboutr 0.9. there is also a running water sound as well sometimes which i never used to have. Does...
hi i hope someone can give some advice. The trouble i am having with my glow-worm 24cxi combi boiler is as follows. Even if the central heating is off via the thermostat if i have the hot water switched on its starts the central heating as well and so the hot water barely gets hot in the...