Search the forum,

fan

A fan is a powered machine used to create a flow of air. A fan consists of a rotating arrangement of vanes or blades, generally made of wood, plastic, or metal, which act on the air. The rotating assembly of blades and hub is known as an impeller, rotor, or runner. Usually, it is contained within some form of housing, or case. This may direct the airflow, or increase safety by preventing objects from contacting the fan blades. Most fans are powered by electric motors, but other sources of power may be used, including hydraulic motors, handcranks, and internal combustion engines.
Mechanically, a fan can be any revolving vane, or vanes used for producing currents of air. Fans produce air flows with high volume and low pressure (although higher than ambient pressure), as opposed to compressors which produce high pressures at a comparatively low volume. A fan blade will often rotate when exposed to an air-fluid stream, and devices that take advantage of this, such as anemometers and wind turbines, often have designs similar to that of a fan.
Typical applications include climate control and personal thermal comfort (e.g., an electric table or floor fan), vehicle engine cooling systems (e.g., in front of a radiator), machinery cooling systems (e.g., inside computers and audio power amplifiers), ventilation, fume extraction, winnowing (e.g., separating chaff of cereal grains), removing dust (e.g. sucking as in a vacuum cleaner), drying (usually in combination with a heat source) and providing draft for a fire. Fans also have several applications in the industries. Some fans directly cool the machine and process, and may be indirectly used for cooling in the case of industrial heat exchangers.
While fans are often used to cool people, they do not cool air (electric fans may warm it slightly due to the heat produced by their motors), but work by evaporative cooling of sweat and increased heat convection into the surrounding air, due to the airflow from the fans. Thus, fans may become ineffective at cooling the body if the surrounding air is near body temperature and contains high humidity.

View More On Wikipedia.org
  1. D

    Worcester Negative Fan Pressure decrease after cleaning heat exchanger

    Hi, I am new gas safe registered. I serviced a old worcester R28 HE Z7-28 system Boiler. found negative fan pressure -3.95mb lower than MI's -4.2mb, Gas rate is 2.82 m3/h, little bit lower than MI'S 2.9M3/H, so clean heat exchanger very well. after that check fan negative pressure, -3.11mb...
  2. J

    Extractor fan for oven?

    I don't know if plumbing include extractor fans, but I was hoping that you could point me in the right direction as to whether self enclose ovens existed so that all of their smoke was funnelled outside, like an top extractor fan, only for oven as they smoke the house out. Thanks!
  3. M

    Worcester fan replaced, pressure now dropped / air in pipes / constant need to top up

    Hi, We recently had a Worcester compact system boiler repaired under warranty where the fan had failed. Since this has happened, the top floor radiator has needed bleeding constantly and additional water added to the heating loop. There's no apparent leak. I'm guessing the boiler is releasing...
  4. P

    Will the shower room need an extractor fan?

    hi , Ive only ever fitted bathrooms and put in what somebody else has already sorted out basically, I'm looking to further my knowledge now and eventually go out on my own and ventilation is something i haven't really got involved in tbh. i have a small shower room that I'm looking at its 1.5m...
  5. johnnybaloney

    Johnson & Starley J25-32 Mk3 - How to open fan chamber door

    Hello, I'm trying to get into J25-32 Mk3 Modairflow (click for image) to give it a bit of a clean and remove corpses of bumblebees which at some point were trying to make it their home. The manual says: I removed the air filter no problem but how to remove that fan chamber door? I tried to...
  6. centralheatking

    Fan Flue Boiler with good internal fitting arrangements

    On behalf of a friend we are looking for which fan flued ng combi or system boiler has a good fitting from inside only. The outside is in Bath and 3/4 Floors up but the outside is above the River Avon so no ladders too high and no scaffold...unless expensive suspended stuff. around 20kw to 30kw...
  7. M

    Changing fan on ideal independent

    If changing a fan on this type of boiler. Is there anyway to test the seal between the fan and the heat exchanger. There shouldnt be a problem as the seal sticks on then you just tighten the fan up to the heat exchanger via a bolt. I thought an analyser around the seal while the boilers...
  8. A

    Buderus 500 28c fan fault.

    Hi guys, it's my boiler I've had an issue with. I've turned the boiler off and drained my system tonight to remove a couple a rads, and as my hot water has beem getting cooler I've gave the plate a clean out too, got filled back up and turned boiler on and was given the 3l fault code which...
  9. J

    Fan running constantly

    Hi We have a logic system 24 boiler. I turned the boiler ofr for 2 weeks while away. Ever since then the fan is running constantly. Even when the burner is off or the programmer is set to off the fan is running. The code on the display is 'c' which i think means that the boiler thinks there is...
  10. Gazzt

    Fan puller that will last.

    Does anyone know where I could get a decent fan puller, other than the universal puller with the Allen key grub screws. Thanks. Riello fan's are stubborn.
  11. S

    Vent bathroom ceiling fan through rosemary tiles

    I need to vent an inline bathroom fan through my roof which has rosemary tiles on and no sarking underneath the tiles. Never done this before so would like your advice to get it right first time. Any help will be much appreciated.
  12. J

    Fan fault (red & green flashing) on my alpha HE CB33 and dropping pressure...any ideas?

    Hi guys... I have a alpha HE CB33 and it’s dropping pressure and coming up with error code (blocked flu or fan fault) any ideas?
  13. CorgiDirect

    Excellent Price on Hayes 2KW Fan Heater Online Quantity Discounts

    Buy 1-4 £9.49 ex VAT each Buy 5-99 £8.49 ex VAT each Buy 100+ £7.75 ex VAT each VIEW HERE
  14. CorgiDirect

    Excellent Price on Hayes 2KW Fan Heater - Best Price Online - Real Bargain

    Buy 1-4 for £9.49 ex VAT each Buy 5-99 for £8.49 ex VAT each Buy 100+ for £7.75 ex VAT each VIEW HERE
  15. P

    USA draft inducer fan or support tall pipe?

    I think a draft inducer TJERNLUND DJ3 or D3 would be better, but might go with pic 1 and 2 if i can tie this up strong against 200mph winds. thoughts? pics Imgur and Imgur
  16. D

    Slow running fan effect combustion?

    Hi all. Before I begin, im talking about older ‘on/off’ fans on atmospheric burners. I am not talking about the newer variable speed fans with zero rated governors on condensing boilers. All I’m wondering is, can an on/off fan run slowly when supplied with 240vac? Would this cause higher...
  17. S

    Vaillant Ecotec Plus 430 - fan starts up briefly in middle of the night

    Hi, I wonder if anyone can help solve a mystery. I've a Vaillant Ecotec Plus 430 boiler (installed as an unvented system) that's about 3 years old and apparently working well. However, in recent months I've occasionally been woken by the boiler fan suddenly starting up in middle of the night...
  18. N

    Potterton Prima F40 fan slow

    Just recently my Potterton Prima F40 boiler failed to start in the morning but had been running fine up to then. I noticed a humming rather than the usual fan sound and suspected a fan problem. On inspection I saw that the fan was turning but not very fast and gently tapped the motor with a...
  19. Peter J Brown

    Worcester highflow 400 pulsating fan

    Hi guys have a highflow 400 with fan that's pulsating, took hoses off air pressure switch and blew them clean and checked venturi. Connected hoses up again and blew down 1 and fan cam on but didn't fire boiler but was running smoothly. Getting 240 to air pressure and also fan. But the power goes...
  20. A

    Wiring up bathroom fan from pull cord. Correct?

    Hi everyone, I have a bathroom fan to wire up tomorrow evening. I have had a look through the instructions but wanted to double check a few things. The fan has no timer just a neutral and live. The light pull cord has just L1 and com and earth connections so can I use this? I am fitting...