  1. D

    Vaillant Turbomax F29 - What's the next step?

    I have a Vaillant Turbomax with an F29 fault. When there is a demand for hot water the gas ignites initially, and the water is heated. However the gas then goes out and then comes back on (not sure if this is usual to control the water temp), it does this a few times but then the boiler fails to...
  2. B

    Vaillant TURBOMax Plus 828E - Partial Load Setting d.00 problems

    Hi, I have a TURBOMax Plus 828E in a small Annex that only has 3 Rads. The boiler Cycles but is only ignited for about 30-40 seconds before reaching target Temp and then goes on pump overrun. Given that there are only 3 Rads and are 'designer' with a total combined KW spec of about 2.5kw, the...
  3. S

    Vaillant Turbomax ignition issue - but only in the evening

    My ancient Vaillant Turbomax has been operating perfectly for the last few years but this week on Monday night I had no hot water or heating. I switched the boiler off and back on and all was fine again. The system is on a Honeywell system which switches the heating on in the morning for half...
  4. JustinD

    Turbomax VUW 242 boiler problem with hot water

    Hi all So we still have this very old boiler but we have still having problems with the hot water, we have called out 3 repair engineer's, but as it's a old boiler everyone seems to guessing, so far they have changed the thermistor, secondary heat exchanger, primary heat exchanger, diverter...
  5. A

    Vailant Turbomax Restarting on hot water demand - any clues?

    Hi, I have a 20yr+ old Vaillant Turbomax VUW 282 with a magaclean (on the flow side) and connected to Hive system for a 4 bed house. Had it serviced by British Gas engineers - but its a mixed bunch that come around and often depends on the engineer quality. Recently had its diverter valve...
  6. B

    Valliant Turbomax Plus boiler

    Hi everyone sorry its my 1st post and to start to beg for info straight away but really have problem with boiler, It comes on when its not supposed to, out side of its program in odd times, had 2 different plumbers come to fix it but still not fixed, one plumber changed the gas valve this do...
  7. D

    Vaillant TURBOmax VUW boiler making "cracking" sound

    We started renting a house nine months ago. The house is just over 20 years old and has a Vaillant TURBOmax VUW boiler. The boiler seems quite old so may have been installed with the house? It's regularly serviced but, as of two weeks ago, it started making a "cracking" sound most of the time...
  8. Harvest Fields

    Vaillant Turbomax cold feed pipe 080945

    Anyone got one of these knocking around there van/garage? Preferably one that doesn’t have a pin hole in the side of it? Thought I would ask before trying to strip the chrome back and solder a couple on to it.
  9. Scott_D

    Vaillant Turbomax noise

    Went to do a gas safety check on a Turbomax today It’s fine in CH Makes this groaning noise in HW if the temp dial is above half way. Diverter? Doesn’t seem to have a bypass
  10. D

    Vaillant TurboMax 242/1 NG Combi Repair

    We have a Vaillant 242/1 NG Combi boiler which has been well serviced over the many years its been in. 1992-96? Combustion readings perfect for CO2% and ratio/ppm etc We have a pretty decent cold mains pressure at all cold outlets, even with a few cold taps open, still a decent flow/pressure...
  11. Bettyboo

    Vaillant no hot water

    Hi All Re: Vaillant Turbomax VUW 242E, 282E- no hot water I have a Vaillant combi that ? has a faulty main control switch or electric /pump problem(I'm guessing). Hot water was not coming on unless heating was also on Then when trying to get hot water to come on without heating on I boiler...
  12. S

    Vaillant Turbomax Plus 828E leak at Main Heat Exchanger connection

    The copper pipe that connects is on the LHS (view from front) and I get a small leak every other day. Do not have to top up frequently, just wipe away. Also has developed an occasional S.54 fault "delay mode due to flow temperature gradient too steep" which means the hot water runs cold with no...
  13. S

    Vaillant turbomax flow sensor

    Evening all, is it possible to test for correct operation with a multimeter, the cold water flow sensor on a turbomax combi. It uses a Hall effect sensor and has the three wires. I did know many many years ago, but with age my mind has eradicated the knowledge:(. It’s no good... this age...
  14. M

    Intermittant F22 in Vaillant Combi Bolier Turbomax Plus 828 E

    I have Vaillant Combi Bolier Turbomax Plus 828 E. About four years ago, the Engineer having serviced the boiler, forgot to open up the water valves of Magnaclean and problem of F22, started since then. Not always but some times F22, appears which does not allow Hot water or Central Heating to...
  15. quality

    Turbomax 837E Combi .

    I repaired the above boiler last year (some may remember the large costs involved) , but cant find the thread. Anyway they want a new boiler that will give them over 10 years operation without being serviced like their old one as they believe in if it aint broke don't fix it. @shuancorbs maybe...
  16. G

    Problem with vaillant turbomax vuw282

    Just looked at an old vaillant turbomax. Set the boiler calling for heat and burner dosent light. So removed front cover and instantly sparks and lights for 30 seconds then goes out a few seconds later repeats lights 30 seconds and goes out. The pumps ok and the fan runs, I pulled fan apart to...
  17. r1k1n

    Vailant TurboMax VUW 242 - No hot water, heating constantly on, water dripping from underneath

    Hello there! Yesterday we turned on the heating as it had been off for a while (due to the heat we've had here). My brother went for a shower but noticed that the water wasn't hot. We reset the boiler (Vailant Turbomax VUW 242 - 2004 install) a couple of times and the problem is still present...
  18. J

    Leak from Vaillant TurboMax Plus 837E pump

    I have a Vaillant TurboMax Plus 837E & it's leaking from the connection to the pump, I have attached photos. Does anyone know how to fix it? Here are the images: Imgur It s leaking from the copper pipe connected to the pump.
  19. L

    Hot water maximum distance??

    Hello everyone I'm new to the forum, I'm looking for some advice and piece of mind. I want to plumb a hot water tap to my kitchen (combi system). Unfortunately I've had the kitchen plastered and I've now decided i want to move the position of the sink, without seriously damaging the nice new...
  20. D

    Valiant turbomax pro 28e - no hot water

    My hot water fires up for a 30 secs or so and then stops. The solid light goes out and flashes (looks like 2 triangles touching at the point), at this point no hot water comes out of the taps. The heating works fine, i also tried to get hot water through the taps when the heating was on, it...