Hi,
Doing a DIY central heating install mostly in speed fit but need to put in some air vents. Because of space only manual ones will fit, but as they need to be soldered and i have no experience of soldering, is there any reason i cant use draincocks instead?
Thanks
Hi All
dealing with a very nice landlord who is trying to plan the layout of a recently acquired first floor flat. The current install is a vented old school boiler that's just been condemned.
Question is what's the lowest flow and pressure you would happily install a Combi on. Testing I get...
Hi All
This is my first post.
Please see attached to this post some pics of the set-up of my boiler.
The pressure has dropped to 0.8bar and I was trying to top up the system by opening the two taps connected to the silver flexi pipe but that didnt work.
I am not sure what I am doing wrong...
eug_1
Thread
black
boiler
lever
oil
opening
pro
pro 28
shaun
vaillant
valve
Hello all engineers ,
I had the following issue today.
went for a change of a prv sitting onto the expansion vessel external.
I just simple changed anger it and the pressure was fine.
But now she told me afterwards their water pressure is pretty low.
They've got 3 bathrooms and a big...
What is the longest length of hot water pipe feeding a tap allowed with out a secondary return,saw a guideline of achieving 50c within 30 secs,this was only a guide not mandatory..cannot access PDF ,bug on pc..
sheff paul
Thread
building
cannot
commercial
hot
hot water
images
length
pipe
shaun
water
I have a warm flow combined boiler and the pipe labeled domestic cold water is leaking where it goes into a metal square box. It also has a junction on it that goes to a silver connection that the hot water goes to and the other side runs into square box as well. There is water coming out at a...
Hello all,
Please can you help me. I've recently moved into a new place and one of the toilets is constantly running as the water is rising above the overflow pipe. I know bugger all about this kind of thing and haven't had any luck in lowering the water level. I've contacted the letting agent...
hi names ,shaun,have a problem anyone can shed some light on,
Ihad installed a year ago 30 cdi condenser boiler(worcester bosch),everything ran fine till this morning,ive lost hot water,checked pressure on gauge 1.5 bar,no fault light on,war working fine yesterday,been through handbook,fault...