Glowworm or glow-worm is the common name for various groups of insect larvae and adult larviform females that glow through bioluminescence. They include the European common glow-worm and other members of the Lampyridae, but bioluminescence also occurs in the families Elateridae, Phengodidae, and Rhagophthalmidae among beetles; as well as members of the genera Arachnocampa, Keroplatus, and Orfelia among keroplatid fungus gnats.
Afternoon chaps, I'm at a lose.
I have just come away from a job wlempty pockets as couldn't fix the problem.
Scenario.
Glow worm 30ci combi won't fire. It sparks, fires on low flame but goes out after 5-10 seconds and then goes to F1. With all cases off right back to burner, it stays on. So...
Hi.
I'm replacing a glow-worm space saver next week. Asked to do either a Worcester Ri or Logic Heat with rear flue.
Makes no difference price wise other than get a filter included with the logic.
I've quite a few RI's so was leaning towards the ideal for a change more than anything...
Hi, over the last couple of days I’ve noticed that there's water dripping from the corner of the boiler. This only happens when the boiler is in use. Up to now the boiler is functioning and heating water and central heating. I would just like to be advised whether this is going to be a major...
Hi There
I hope you can help or point me in the right direction.
I have a Glow Worm 38CXI boiler. The Central Heating is working perfectly however a few weeks ago we started to experience a problem with the hot water. When running the shower or putting a big demand on the hot water tap the...
Please could anyone advice. I have a 36 y.o. Glow Worm Space Saver 38. I have had it for the last 6 years when bought my current house. I serviced it for the first two years but then stopped servicing in fear that it could be condemned just for being old an inefficient or no spare parts. I did...
Hi guys, I've just wasted so much time trying to figure out how do I achieve low and high firing from this boiler..
I've read the manual many times but still don't make sense.
I did a replacement boiler change which should of taken half the day not 12 hours! Due to not managing to commission the...
Hi all, first post but have a major issue that's causing me headaches. My system boiler (Glow Worm Flexicom 18hx) continues to cycle to keep itself up to temperature, even without any demand from the programmer (Drayton Lifestyle LP 522) which is also causing the pump in the upstairs airing...
at the moment i have 5 radiators 1 double and 4 single panel. they all are 40 odd years old , i want to relace all with double panel ones. would my boiler cope ok ?. it is a condenser boiler and the tank in the loft is open vented. hope some one can give me any advice. thanks.
Hi I’d really appreciate some guidance as I’m now utterly confused. My boiler (compact 100e) seems to be working ok except can be very slow to produce hot water from the taps (starts off cool slowly warming to reasonably hot, particularly if CH has been off), and also at times just luke warm...
Hello Forum,
I've noticed at times that my boiler is heating in a very short cycle.
30 seconds on at full flame, heating to 65c.
30 seconds off, cooling to 37C.
30 seconds on at full flame, heating to 65c.
It cycles like this for 10mins or so, then goes quiet for a period of time, then...
Advice, I'm wondering about the glow worm combi that has the mechanical time clock displayed on the front panel, can this be disconnected? As I'll be installing it in the loft and using the exciting room stat/ programmer.
Not much experience in glow worms and I don't do electrics.
Hi, need some help please.
we have moved into a new house which has glow-worm easicom 28 installed. The heating is set to 70 and hot water is set to 60 on the boiler and the hive is set to 22c
The problem we are having is 1) that it takes almost an hour for the radiators to start heating or...
Looking for some guidance please.
I have above boiler, its the 35 store, been in 6 years and now it trips out (at boiler reset on boiler) when calling for hot water, after about 4 or 5 miinutes run time. central heating no poblems, had heat exchanger replaced about 2 years ago and high temp...
Hi, can anyone clarify wiring and Honeywell 927 and BDR91 to a glow work ultimate 3.
The BDR91 is currently set up as a 240v feed with 4 core cable.
LNE are going straight from the receiver to the boilers LNE. I then have L bridged to A in the receiver. Does B from the receiver just go to RT...
Hi all
Got a problem with above boiler, fault code f81 and discharge from vent, central heating working OK.
I think it may be a faulty temp sensor causing overheating, gauge shows 55degrees.
Any thoughts very much appreciated
Cheers .
Hiya fella, thanks for the acceptance, I'm traditionalself taught as my company just did installs However I'vegot a a glow worm 56 bbu, pilot working fine (according to customer) but no main burner .. what's thegeneral testing of gas valveis it
1. Interupter
2. Thermostat
3. Resistance on...
Hi all
Can someone steer me in the right direction diagnosing a glow worm 45/2 back boiler issue. It’s cutting out after about 10 minutes in operation. Always serviced, clean as a whistle. Pump is ok, header tank is ok. Motorised valve is ok. Any thoughts would be much appreciated.
Many thanks
Morning all,
I have a slight leak issue with my combi boiler. I have noticed that there seems to be some water leaking from the bottom of my boiler, when I removed the cover just to see if I could spot the source I noticed there wasn’t really anything obvious until I accessed behind the...